Description
First, System introduction SS-700 flue gas VOCs monitoring system is based on Hj/t80, Hj/t75, hj/t76 and other related standards, using extraction method sampling, configuration based on advanced gas chromatography, mass spectrometry and other separation technology and hydrogen flame ionization detector (FID), Optical ionization detector (PID) and other detection methods, the components of volatile organic gases such as total hydrocarbon (THC), non-methane total hydrocarbons (NMHC), aromatic hydrocarbons and esters in the exhaust gas are measured according to the composition and testing requirements of each sample in the analysis project, which can meet the requirements and analysis frequency of the analysis project.
At the same time, the optimization of the instrument configuration can maximize the utilization rate of the instrument and ensure the continuity and reliability of the sample analysis work.
The analysis system fully considers the sample gas condition and dew point, and designs the pretreatment system to prevent the crystallization condensation and the component concentration change of the sample gas. The instrument adopts special chromatographic column combination, Central cutting plus back blowing technology and hydrogen flame ionization detector (FID) technology to detect.
FID hydrogen Flame ionization detector is a typical quality detector, which measures the mass change velocity of a component in gas chromatographic carrier gas, and the response value is proportional to the quality of a component entering the detector in the unit time.
Second, the characteristics of the product 1.
System pipelines are imported clean stainless steel tube to reduce adsorption; 2.
The system adopts whole calibration to eliminate the effect of small amount of adsorption on the measurement. 3.
The analytical method is consistent with the calibration method, and the Gc-fid method is used to detect; 4.
The whole process of high-temperature 180 ℃ with heat sample transmission, high-temperature FID detection, to avoid high boiling point VOCs adsorption and condensation, more accurate measurement; 5.
Continuous operation Maintenance-free design, automatic cycle operation, the real sense of online analysis; 6.
The whole flow road insulation 180 ℃ design, no water vapor condensation, to avoid corrosion degradation of parts, suitable for high-temperature/GAO/corrosive working conditions; 7.
Non-methane total hydrocarbon and benzene, toluene, xylene and other parts of the simultaneous monitoring.
Iii. Areas of Application For chemical, printing, pharmaceutical, rubber, spraying coating, electronic semiconductors, synthetic leather, such as organic emissions online monitoring, organic waste gas recovery.
Manage pre/post online monitoring.
Iv. Technical Parameters
Analysis of monitoring points to range of components
Flue gas vent flue non-methane total hydrocarbon (NMHC), volatile organic compounds (VOCs) 0-1-10-100ppm (other amount Cheng)
Temperature 0-300 ℃
Pressure -5-5kpa
Flow rate 0-30m/s
1, detection capacity: methane, non-methane total hydrocarbons and total hydrocarbons, toluene, ethyl benzene, xylene;
2. Range: Methane (0.1-10000) PPM, non-methane total hydrocarbon (0.05-10000) ppm, benzene (0.1-10000) ppm (optional);
3, detector: Hydrogen flame ionization detector (FID);
4, detection limit: ≤0.1ppm (methane), 0.05ppm (non-methane total hydrocarbon), ≤0.1ppm (benzene);
5, repeatability: rsd≤3% (total hydrocarbon/benzene);
6, accuracy: ±1%F.S;
7, 0 point drift: no drift;
8, the range drift: ±1%F.S;
9, sample flow rate: Analysis of Samples: 50ml/min Sample update rate: 3-10l/min
10, Analysis cycle: Non-methane total hydrocarbon
- Flue Gas Monitoring System
Production Capacity:
Not informed
Delivery Timeframe:
Not informed
Incoterms:
Not informedPackaging Details:
Not informed
More about
SENSHANG INSTRUMENT
Not informed
Not informed
Not informed
Year
Established
Business type
- Industry / Manufacturer
Keywords
- CESM
- VOCS
- TDLAS system
- gas analyzer
- gas monitoring system
Contact and location
- Carol Zhong
- +86 731 xxxxxxxx
- Changsha / Hunan | China